HL 105 Three-way mixing valve training panel
HL 105 Three-way mixing valve training panel
GUNT HL 105 provides hands-on study of a three-way mixing valve, regulating temperature and flow in heating systems. Students learn the principles of hydraulic control and efficient mixing of hot and cold water. The panel offers real experimental conditions for analyzing flow dynamics and the valve's response to temperature changes, essential for effective heating system management.
More about the productGUNT HL 105
Training panel is designed for practical learning about heating systems and plumbing.
It features a three-way mixing valve (DN 20), a circulating pump, and four rotameters for flow measurement.
Additionally, it includes four bimetallic thermometers for temperature monitoring and two heating water connections (DN 15) along with two boiler water connections (DN 15).
A differential pressure overflow valve ensures safe operation.
The system uses quick-release couplings for easy water connections.
Technical Data & Specifications
- Pump:
- Power consumption: 70W
- Maximum flow rate: 60L/min
- Maximum head: 4m
- Three-Way Mixing Valve:
- Setting angle: 90°
- Opening time: 100s
Measuring Ranges
- Flow Rate:
- 3x 150…1700L/h
- 1x 40…400L/h
- Temperature: 0…100°C
Power Supply
- 230V, 50Hz, 1 phase
- 230V, 60Hz, 1 phase
Dimensions & Weight
- LxWxH: 1650x700x1850mm
- Weight: ~112kg
Required for Operation
- Hot water supply: 1800L/h
- Cold water connection
- Drain
- Quantitative unit
- ks