More than a purchase. You get service and expert advice. Ask which products and combinations are recommended for you.
The ultimate tool for High Performance Ventilation training
Training tool allowing measurement and recording of insufflated volume, tidal volume, manual ventilation frequency, in real time, to practice ventilation in accordance with ERC and AHA recommendations. EOlife X enables training on adult and paediatric (> 1 year) manikins.
TWO TRAINING MODES. FOLLOW THE GUIDE OR TEST YOUR SKILLS.
Blind mode.
This mode records your ventilation sessions without visual guidance. Export your ventilation data via Bluetooth to measure your progress*.
Monitored mode.
This mode visually guides you through your ventilation sessions. Practice as if using an EOlife.
* Requires the EOlife Connect app, available on the Apple Store and Google Play Store.
TRACK YOUR SKILLS PROGRESS OVER TIME.
Thanks to the EOlife® Connect app, you can download and save each of your Training sessions to allow Booster Training and Spaced Learning as recommended by AHA to improve CPR skills retention.
EOlife® Connect app is the only solution that offers a detailed analysis of the ventilation parameters, thus allowing to focus on the areas to correct and improve.
COMPARISON MATRIX
EOlife
EOlifeX
Can be used on patients (CE marked, FDA cleared)
YES
NO
Can be used on a manikin
YES
YES
Possible deactivation of the leakage alarm
NO
YES
Type of patient / manikin
Adult
Adult / Child (>1 year)
Selection of ventilation mode (CPR/Continuous)
YES
YES
Recording and data export
YES (requires the EOlife Connect MD application)
YES (Requires EOlife Connect on Apple Store or Google Play Store.)
Type of sensor
Single-use (Flowsense)
Reusable (Flowsense X)
Accessories
Battery and charger included. (transport case and sensor to be purchased separately)
Battery, charger, transport case, and 1 sensor included
TECHNICAL SPECIFICATIONS
Dimensions (L × W × D)
130 mm × 75 mm × 30 mm
Weight
170 grams ±5 grams
Operating conditions
Temperature from 0°C (32° F) to +40°C (104° F)
Relative humidity from 15% to 95% (non-condensing)
Atmospheric pressure from 620 hPa (altitude of 4000 m) to 1060 hPa (altitude of -500 m)
Transient operating conditions (up to 20 minutes maximum)
Temperature from -20°C (-4° F) to +50°C (122° F)
Relative humidity from 15% to 90% (non condensing)
Run time
min 5 hours
Ingress Protection against solids, dust, and water intrusion
IP44 (configuration in use, meaning the device connected to its battery and sensor)
Measurement accuracy
Volume measurements are based on FlowSense® sensor measurements and are expressed in mL for the BTPS (Body Temperature and Pressure, Saturated). The measurement accuracies of the parameters displayed on the screen are as follows: • Vi (insufflated volume): ± 4.9% of the actual measured value under normal conditions of use • Vt (tidal volume): ± 5.5% of the actual measured value under normal conditions of use • Freq (ventilation frequency): ± 1 cycle per minute
FlowSense® data: • Flow range: ± 250 slm (standard liters per minute) • Dead space: < 10 ml
Note: Some types of BVM may affect the measurement accuracy due to their design (non-laminar outgoing airflow). A slight measurement deviation may be observed but has no impact on compliance with regulatory requirements.